Menu
Content not available
First of all, please note that this B2B platform is intended for installers and companies that make regular purchases.
Reasons for not activating:
Email address: We do NOT accept email addresses from general providers such as Gmail, Hotmail, Outlook, etc. Your email address must be associated with your company's domain. This ensures a more secure and reliable platform for all users.
Business activity: Your business activity must be directly related to our products or the field of solar energy installation. Our B2B platform is specifically aimed at companies that are actively involved in these areas.
If you do not comply with this, the account will not be accepted and you will therefore not be able to log in. Although we cannot activate your account, you can still place orders on our website etronixcenter.com.
If you meet all of these requirements and have registered, we will check it and you will automatically receive a message if your account has been approved. If you do not meet these requirements, the account will be deleted and you will not receive a message because the information above has already been indicated as meeting these requirements.
Our systems have detected that you are visiting us from United States.
UK, NON-EU and B2B customers note!
All prices and shipping costs are VAT FREE rated in our webstore. Upon arrival of your order you might be subject for VAT / Duty taxes payments.
Manufacturing number | BBA000100100 |
The problem: the service life of an expensive battery bank can be substantially shortened due to state of charge unbalance
One battery with a slightly higher internal leakage current in a 24V or 48V bank of several series/parallel connected batteries will cause
undercharge of that battery and parallel connected batteries, and overcharge of the series connected batteries. Moreover, when new cells
or batteries are connected in series, they should all have the same initial state of charge. Small differences will be ironed out during
absorption or equalize charging, but large differences will result in damage due to excessive gassing (caused by overcharging) of the
batteries with the higher initial state of charge and sulphation (caused by undercharging) of the batteries with the lower initial state of
charge.
The Solution: battery balancing
The Battery Balancer equalizes the state of charge of two series connected 12V batteries, or of several parallel strings of series connected
batteries.
When the charge voltage of a 24V battery system increases to more than 27,3V, the Battery Balancer will turn on and compare the voltage
over the two series connected batteries. The Battery Balancer will draw a current of up to 0,7A from the battery (or parallel connected
batteries) with the highest voltage. The resulting charge current differential will ensure that all batteries will converge to the same state of
charge.
If needed, several balancers can be paralleled.
A 48V battery bank can be balanced with three Battery Balancers.
LED indicators
Green: on (battery voltage > 27,3V)
Orange: lower battery leg active (deviation > 0,1V)
Orange: upper battery leg active (deviation > 0,1V)
Red: alarm (deviation > 0,2V). Remains on until the deviation has reduced to less than 0,14V, or until system voltage drops to less than
26,6V.
Alarm relay
Normally open. The alarm relay closes when the red LED switches on and opens when the red LED switches off.
Alarm reset
Two terminals are available to connect a push button. Interconnecting the two terminals resets the relay.
The reset condition will remain active until the alarm is over. Thereafter the relay will close again when a new alarm occurs.
Even more insight and control with the midpoint monitoring function of the BMV-702 Battery Monitor
The BMV-702 measures the midpoint of a string of cells or batteries. It displays the deviation from the ideal midpoint in volts or percent.
Separate deviation percentages can be set to trigger a visual/audible alarm and to close a potential free relay contact for remote alarm
purposes.
Please see the manual of the BMV-702 for more information about battery balancing.